Changes of P630 Pro versions from 1.4 and up

 

 

 

Changes from version 1.3-w to 1.4

 

a)        In utility mode process data select curve menu selection of Ch A, B, C and D was set inactive if not used by other functions. This is corrected.

b)        An AI mode has been added to utility process data in save menu.

c)        An AI mode has been added to edit menu. The AI channels must first be processed in utility.

d)       An AI mode has been (auto learning to modify limits). This function must first be created in utility and then activated in edit mode for actual settings.

e)        In BL-menu a gain function is added. This enable a better test due the display is 12 bit collected data is 24 bit.

f)         Hi-2 test did only accept input 11 or 21. Input 12, 22, 13 and 23 are now added as valid input for Hi-2 test.

 

 

Changes from version 1.4 to 1.4-a

 

a)        Hi-2 test did only accept input 11 or 21. Input 12, 22, 13 and 23 are now added as valid input for Hi-2 test.

b)        Check for prober sample rate added.

 

 

Changes from version 1.4-a to 1.4-b

 

a)        Modified sync between threads to handle Seraph8 driver 4.090. Sweep did lock if windows 7 Pc were powered on. Was ok with a restart. Driver 3.089 was ok.

 

Changes from version 1.4-b to 1.4-c

 

a)        In utility process statically data in manual mode user serial number was not displayed. The user serial number was displayed for format 21, 30 and 31. Format 32 is now added to display user serial number.
The user serial number can be displayed by the “results” in p630 version 1.4 to 1.4-b.

 

Changes from version 1.4-c to 1.4-d

 

a)      If control was used selected in Hw Config Menu the I/O code 7 selected in setup menu was not saved. This is corrected.

b)      If old reference databases is used the databases is automatic updated to new formats. This update was not done for the PH_CURVE.DBF, This result for an error id test points over 250 was used.
A check is now added.

 

Changes from version 1.4-d to 1.4-e

 

a)      I/O input bit 3 did not delete last saved record in saved statistics databases if activated. This is corrected.

b)      Warning when saving changed curves that this got an impact in saved ai-curve when ai-option was disabled is corrected

c)      In hardware setup the flag in Ave Result did not save measured test result in the file a4_ave.txt file. This is corrected.

d)     In edit menu-resonance mode “Hz” added to R and F measured values.

e)      In hardware setup the user text for approved, rejected and noise could sometimes add wrong signs end of text. This is corrected

 

 

Changes from version 1.4-e to 1.4-f

 

a)      If screen statistic was set off in global mode a display position error could happen when a test was auto-repeated. This is corrected. 

b)      Reference curves on BL displayed last reference point wrong. This is corrected. The display error did not affect the measurement and test

c)      Bl smooth off was missing. Bl smooth off added.

d)     In run-mode when results was set ON with DBF format in global menu the system could loop and damage the A4STAT.DBF file. This depends of the pc brand after many tests. Often seen on W32 bit pc’s.
This problem is seen from version 1.4-b. The problem is corrected.

e)      Smooth in Bl made wrong smooth at the first measured points. This is corrected.

f)       Hi-2 did not work correct when a reversed sweep was used. This is corrected.

g)      In Hardware Config Setup a sample rate of 192000 added.

 

 

Changes from version 1.4-f to 1.4-g

 

a)    Cursor readout in Ch B and Ch d was wrong when filter was used with +20 db gain if gain on filter was set to +20db AND filter was set off. This is corrected so cursor readout set the +20 db gain to off when filter is off.

b)   More valid dongle keys added to system.

c)    In hardware configuration the selection of output pulse sign have been added.

 

 

Changes from version 1.4-g to 1.4-h

a)    When Curve Editor under Edit Curve menu was used and empty frequency and value was entered an unpredicted result could be returned. This is corrected.

b)   Start background picture is now rescaled when window size is changed.

c)    List of stored types in Utility Process data did list 64 types. This is changed to 512 types.

d)   In Utility Process data Replace part of curve the Min curve did not work for BL curve. This is corrected.

e)    Seraph 8 MKII added to ASIO valid driver list.

 

Changes from version 1.4-h to 1.4-i

 

a)    When chain was used in run-mode and the first and last test used different test points the last test was displayed with the first test no of points. This is corrected.

 

 

Changes from version 1.4-i to 1.4-j

 

a)      At the sweep a “Slow” function added. The minimum step rate between each frequency step can be slowed approximate 4 times slower than normally sweep.

b)      This reduces the delay between sound from speaker and microphone depending distance.  Example 10 kHz could be displayed at 15 kHz if sweep speed was too fast.



Changes from version 1.4-j to 1.4-k

 

a)      The Ai function did not work correct in run-mode. This is corrected.

b)        Output compress did not work. This is corrected..

c)        Seraph 8 MKII driver version 4.38 added to ASIO valid driver list.

 

 

Changes from version 1.4-k to 1.4-l

                     

a)        Mouse functions added

b)        A new test “R-23” have been added. This is relative distortion test, a ratio between some distortion types.

c)        In Edit-mode Select Display function have been expanded to selection a single curve in each display channel (A-D).

d)       In Run-mode Select Display under Cursor have been expanded to selection a single curve in each display channel (A-D).

e)        In Utility-mode Process Statistical Data, Select Display under Cursor has been expanded to selection a single curve in each display channel (A-D).

f)         Import 2. And 3. Reference curves used in channel A did not check if the curves were set off if present. This is corrected.

g)        In Edit-mode curve convert, Scale, T-curve and Gain Adj. submenus have been improved due to no b)

b)        The update speed of graph curves updated. In utility process mode with approximate 3-4 times.

c)        A second brand of dongle has been added to system.

 

 

Changes from version 1.4-l to 1.4-m

                     

a)         In utility processing in manual mode curves was blanked out by the previous data set. This is corrected. This error was only in version 1.4-l.

b)        In utility mode if manual mode was used and then auto mode was used afterward the last date and serial number was displayed from manual mode. This is corrected.

c)         In utility mode if data file was huge no info was displayed. You may be thing the program did not work. Info added “Please working – Processing data”.

 

 

Changes from version 1.4-m to 1.4-n

                     

a)         In edit mode not all curve limits was saved if the selected type was changed in number of test points.

This did only happened if previous (1 before) saved type had less selected points than the current saved version and the version before the previous version (2 time before) was bigger than the previous.
This error is corrected.

 

 

Changes from version 1.4-n to 1.4-o

                     

a)      New driver added. MARIAN Family driver added.

b)      If chain was used and resonance test was used in channel C the curve was changed to reject color if first test was called and rest was test was displayed. Test was ok. This is corrected.

c)      If R2 test was used and later disabled the test got a reject as total test even it was not used. This is corrected.